19466
... Just because the trusses are at 600mm doesn't mean the Veluxs are restricted to 550mm widths. If you don't mind cutting your trusses that is. Most large ...
RichardOwen
richard_owen...
Offline Send Email
Aug 1, 2003
7:10 am
19467
... the 4 Velux ... trusses ... high ... that is ... span is ... David, you can put your velux's where you like, they don't need to be on a truss spacing. ...
etj_webster
Offline Send Email
Aug 1, 2003
7:11 am
19468
... Bert, I have added a pic of the mat in our wet room to the photos section, in my folder (JohnW). You can see how I have cut the mat to fold it back on...
etj_webster
Offline Send Email
Aug 1, 2003
7:15 am
19469
Just a few further comments on this... ... Are you planning to span this in one length, with no supports between ? I'm not sure I understood this - is the 7m...
etj_webster
Offline Send Email
Aug 1, 2003
8:15 am
19470
Just a reminder on how to join to join the UK_Selfbuild group - been asked to re-post this for people who wish to send to colleagues etc. The UK_Selfbuild...
UK_Selfbuild@...
Send Email
Aug 1, 2003
8:35 am
19471
... Yes, the 7.3 metre is wall to wall, normal pitched roof, because of the 22.5 degree pitch there is no potential for room in roof and it's not needed for ...
David Chapman
avonlogic
Offline Send Email
Aug 1, 2003
9:43 am
19472
... You should be able to span that with trusses no problem (will depend on which type of tiles etc you use), but have you thought that this sloping ceiling...
etj_webster
Offline Send Email
Aug 1, 2003
10:16 am
19473
David Have a look at this solution http://www.milbankroofs.co.uk/index.htm - I am considering it with large timber purlins and ridge pole and large timber A ...
Andrew Doyle
andrew_w_doyle
Offline Send Email
Aug 1, 2003
10:28 am
19474
Dave, I have looked at using sips and I think you are getting close to the max distance between supports at about 4 mtrs from wallplate to ridge, and that is...
ian charles
marsac23
Offline Send Email
Aug 1, 2003
10:44 am
19475
... Well it's certainly the product, does all I need and because I've got gable ends and a simple rectangle shape the purlins to support and general design ...
David Chapman
avonlogic
Offline Send Email
Aug 1, 2003
3:33 pm
19476
David Yes - I think your sums are similar to mine - except I also factored in the following: - is 34/m2 for Fermacell ceilings - probably pasterboard is ok...
Andrew Doyle
andrew_w_doyle
Offline Send Email
Aug 1, 2003
4:31 pm
19477
Our span is almost as much, and went for trusses at 400mm centres because we looked like having thick & heavy slates (there's a name for them, which I forget)...
Chris Hunter
chris_j_hunter
Offline Send Email
Aug 1, 2003
6:39 pm
19478
Hmmm ... thanks for that ! Changing the subject, but slightly ... Rick's often mentioned Mems ... have just received a brochure from them ... which raises a...
Chris Hunter
chris_j_hunter
Offline Send Email
Aug 1, 2003
6:52 pm
19479
Interesting ... Maybe they would sell it ? Or rent it ? Too far away for us, of course ... Chris...
Chris Hunter
chris_j_hunter
Offline Send Email
Aug 1, 2003
6:53 pm
19480
Interesting product (Milbank) ... doesn't mention sound isolation (unless I missed it) ... and I wonder how SIPs rate in this regard ... anybody seen anything...
Chris Hunter
chris_j_hunter
Offline Send Email
Aug 1, 2003
7:00 pm
19481
Chris, (note all this is from memory so some of the finer details may be a little blurred . . .) I love it, I think it was/is a great idea and a great way to...
Hawes,Timothy Edward ...
haweste
Offline Send Email
Aug 1, 2003
7:17 pm
19482
... alone - this compiled from those that donated their >services etc. That makes the Devici 'Zero heat' house look quite a bargain! Nick W....
Nick Whetstone
jomangouk
Offline Send Email
Aug 1, 2003
8:28 pm
19483
Tim - As you say, £300k seems a bit high ... but the idea of repeating it (bettering it, presumably, each time) around the country sounds interesting ......
Chris Hunter
chris_j_hunter
Offline Send Email
Aug 2, 2003
12:45 am
19484
It was a bit more complex than "simply cutting the trusses" when I did my first Velux window into a 36 year old roof. 1. I nailed 4x2 bracing timbers across...
Meg & Peter Broome
ukthorn
Offline Send Email
Aug 2, 2003
7:35 am
19485
In a moment of weakness I ordered a bathroom suite from a well-known flat pack high street retailer - total cost around 1100 GBP. This company delivers...
Chris Hall
Chris.Hall@...
Send Email
Aug 2, 2003
8:31 am
19486
Chris, You could value your time at a very reasonable 15 pound/hour - charge a reasonable time for each leter/phone call the way a solicitor would, estimates...
Andrew Doyle
andrew_w_doyle
Offline Send Email
Aug 2, 2003
10:02 am
19487
Why not just take the £100, tell us all who they were (so we can take the appropriate action - avoiding them or being wary of them), and just get on with your...
Chris Hunter
chris_j_hunter
Offline Send Email
Aug 2, 2003
6:08 pm
19488
Sounds good ... wonder if Hansgrohe could help with the anscilliary kit (their stuff seems to be everywhere these days, and I'm sure they'd want it ...
Chris Hunter
chris_j_hunter
Offline Send Email
Aug 2, 2003
6:11 pm
19489
Not having a new MEM cat to hand...(roof is off the office and most cats have been mothballed!) ... Non-standard sockets are like normal BS1361 sockets, but...
impvan
Offline Send Email
Aug 2, 2003
7:46 pm
19490
... brought about ... of everything ... While I agree that the compensation culture harms us all, I really don't think it applies here. As for...
impvan
Offline Send Email
Aug 2, 2003
8:14 pm
19491
You'll all have to excuse my ignorance, but what's a SIP roof? I ask as the builder of a very traditional cut rafter-and-purlin roof! BTW - re exposed...
impvan
Offline Send Email
Aug 2, 2003
8:26 pm
19492
Aha ... many thanks ... Chris...
Chris Hunter
chris_j_hunter
Offline Send Email
Aug 3, 2003
1:29 am
19493
... I think it means Structually Integrated Panel and best way to describe it is the sort of roof you would put on a normal domestic apex shed ! It's a flat ...
David Chapman
avonlogic
Offline Send Email
Aug 3, 2003
9:46 am
19494
... about ... everything ... Surely the reason things are more expensive than they should be or profits are not as high as they could be is because of poor...
Chris Hall
Chris.Hall@...
Send Email
Aug 3, 2003
10:08 am
19495
Following on from thoughts on SIP roofs. I know that the standard 600mm spacing is to make it easier to use 1200x2400 plasterboard sheets. What problems would...
David Chapman
avonlogic
Offline Send Email
Aug 3, 2003
10:13 am