You can set the sort order of messages? Just click on the link in the date column. Your preferences will be remembered, so you don't have to do it again when you return.
Mike, to clarify here, you connect the resistor to the SPROG, in one of the "track" connections, and then it will work for any decoder. You do not do anything...
Hi Mike, No, just put the resistor on one of the track wires leading out of the SPROG (I mentioned the red and black wires 'cause I'm wiring mine directly into...
Hi, Does the SPROG 3 have an internal circuit breaker or any other kind of protection in case the maximum output current is exceeded? If so, how do you "reset"...
Hi all, I wonder if any one has come across this problem. I have just instslled a train save (Guagemaster) decoder into one of my locos and my sprog 2 will not...
In Mike's case, programming is working fine, it's turning the power on to run locos that is the issue. I am working on a theory but haven't recreated the...
It does have a current limit, which auto resets and tries to restore the power. This repeats, with the track LED flashing quickly, until the the short is...
Hi Andrew sorry i didnt get back to you but been out today, when the loco is on the test track and i click on new loco then click on read type from decoder the...
... You can just use standard nmra type to set it up. This will allow youn to open programmer. It is because the Trainsave decoder is not on your list. You...
... I think this link will take you there iof you are a member of JMRI yahoo group http://groups.yahoo.com/group/jmriusers/files/Decoder%20files/Gaugemaster/ ...
Hi Graham I have now got to read your replys and thanks vary much for the info i will try using the nmra some time tomorow and will let you know how i get on ...
Peter, You'll find the correct file (TrainSave_TSV01a v0.2.xml) on the JMRI user group file section. Rob. ... [Non-text portions of this message have been...
Peter, That means that the SPROG is not seeing the decoder acknowledgement at all, so using standard NMRA settings will not help. Do you have any locos with...
Hi all. Thanks for all the answers and help, I have many locos that i can run in sprog comand some sound and others that i have wired in the decoders myself. ...
... Sprog dose see the loco but because the decoder definition is not in the file it will report No Loco Found. Thanks. That's a new on on me! Andrew...
Is it possible to download additional sounds, including LokSound's own sound files, into LokSound V4 type decoders via Sprog 11 without using a LokProgrammer...
I'm using DecoderPro3 and Sprog11 and am trying to create bespoke throttles for various locos. I'm editing the standard throttle buttons/keys to show the...
Hi, Has any used a Sprog 11 with windows 7? Did you experience any problems with drivers for win 7? Are there any problems I should know about? I have ordered...
Hi David, I have recently switched to Windows 7 and had no problems at all but I use a USB - Serial converter with my serial SPROG 2. I identified the COM port...
I have exactly the same problem. Didn't work on one laptop so installed on another. Work great right off. Shut down packed up the laptop took it to a train...
... Mark, When you have PanelPro loaded, if you go to the Sprog menu and select "Sprog Version" what response do you get? It should return the firmware...
Mark, When you broke the system down to move, did you happen to disconnect the power supply? I went nuts one day trying to figure out why two new Sprogs would...
Hallo, I'm new to this list but may be you know me from other lists ;-) I have a question about SPROG II (USB Ver 2.7): I have tried many locos with different...